Air Handling Unit
Air Handling Unit
  • Features
  • Technical Data
  • Application
1, Choose best materials, main components are from China top brand or imported.
 
2, The modular casing design, easy interchanging each other. easy install,easy transport,easy maintaince.
 
3, Unique no-cold-bridge design, improve the insulation and air tightness, total air leak rate ≤2.5%.
 
4, With dynamic balanced double inlet Centrifugal fan, with good air dynamic features, and accurate working, high efficiency, low vibration, low noise etc. 
 
5, High efficient heat exchanger coil, ensure to provide the enough cooling capacity to the unit. And also high efficient breakwater panel is provided if required, water flow in coil ≤3×10-4kg/kg.
 
6, Strong structure, good looking and permanent color.
 
7, Reasonable inside structure, with the suitable space for maintenance and cleaning.
 
8, Casing sheet: Provide doubleskin construction constructing Sandwich type comprising 0.5mm thick galvanized internal and external skins and with 30mm thick polystyrene insulation of minimum 45kg/m3 density. Good airproof material is use between the casing and the frame to reduce the rate of the air leak.
The combined air handling untis are modular designed ,each modular can be used independently and can also work together and company with fan coil units to add refresh air. Not only reduce operation costs and energy saving, but also optimize air quality and create a congnitive indoor space to meet the human health requirements.
GT-ZKW-()CW
Model:GT-ZKW-()CW 300 350 400 450 500 550 600 700 800 1000
Nominal air volume m3/h 30000 35000 40000 45000 50000 55000 60000 70000 80000 100000
Static Pressure 1* Pa 600 600 600 600 600 800 800 800 800 900
Blower Power 1* Kw 18.5 18.5 22.0 22.0 30.0 30.0 37.0 37.0 45.0 55.0
Heating capacity 2* Kw 72 84 96 96 120 120 150 180 180 210
Humidifying capacity3* Kg/h 21 30 30 45 45 60 72 90 100 120
Filter 4* Type Primary effect G4(middle effect F8/Nanocrystalline carbon filter)
Power 3N-380V-50Hz
 
Cooling 4 rows return air Return air(kw)5* 179 210 245 277 306 340 375 440 504 590
Water flow(m3/h) 28.2 36.2 42.1 47.6 53.0 58.2 64.6 76.1 86.8 101.3
Water resistance(kPa) 50 20 27 29 32 35 40 25 35 48
Pipe diameter(DN) 80 65*2 65*2 80*2 80*2 80*2 80*2 100*2 100*2 100*2
4 rows fresh air All fresh air(kw)5* 310 360 410 456 510 570 600 720 840 1020
Water flow(m3/h) 55 62.5 72.2 78.4 87.6 98 103.1 123.7 144.3 175.3
Water resistance(kPa) 35 40 31 38 43 48 36 48 35 50
Pipe diameter(DN) 80*2 80*2 100*2 100*2 100*2 100*2 80*3 80*3 100*3 100*3
6 rows return air Return air(kw)5* 210 240 280 310 350 380 400 490 560 680
Water flow(m3/h) 36 42.5 48.1 52.3 60 66 68.8 84.2 96.6 116.8
Water resistance(kPa) 25 30 35 40 49 26 34 39 32 40
Pipe diameter(DN) 100 65*2 80*2 80*2 80*2 100*2 100*2 100*2 80*3 80*3
6 rows fresh air All fresh air(kw)5* 420 456 532 590 665 720 760 930 1060 1290
Water flow(m3/h) 72.5 78.4 91.4 101 114.3 123.7 130 160 182 221.6
Water resistance(kPa) 40 45 50 38 42 48 31 40 50 45
Pipe diameter(DN) 100*2 100*2 100*2 80*3 80*3 80*3 100*3 100*3 100*3 125*3
8 rows return air Return air(kw)5* 264 290 330 380 420 470 480 590 680 820
Water flow(m3/h) 44.2 49.8 56.7 65.3 72.7 80.8 82.5 101.4 116.8 141
Water resistance(kPa) 29 35 40 31 36 42 45 30 40 42
Pipe diameter(DN) 80*2 80*2 80*2 100*2 100*2 100*2 100*2 80*3 80*3 100*3
8 rows fresh air All fresh air(kw)5* 500 550 630 720 800 890 910 1120 1290 1560
Water flow(m3/h) 85 94.5 108.3 123.7 137.5 153 156.4 192.5 221.7 268
Water resistance(kPa) 40 38 46 50 38 45 35 40 45 42
Pipe diameter(DN) 100*2 80*3 80*3 80*3 100*3 100*3 100*3 125*3 125*3 100*4
 










Application:
The units are widely used in the air system of many inductries like mechanical ,electronic, textile,medical,chemical,energy and foo inductries ,etc. the units are also ideal solution for restaurants, office buildings,hospitals,theaters,supermarkets and palaestra.
Product Catalog