MWWL Sea water cooled screw chiller unit parameter | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Model Parameter |
160S | 210S | 280S | 320S | 400S | 540S | 600S | 720S | 810S | 920S | 800D | 1080D | 1200D | 1440D | 1620D | 1840D | |||
Cooling Capacity | 50HZ | KW | |||||||||||||||||
60HZ | |||||||||||||||||||
Throttling Methods | Liquid crystal/Touch automatic computer control/Thermal expansion valve/Electronic expansion valve | ||||||||||||||||||
Refrigerant | R22/R407c | ||||||||||||||||||
Refrigerant Charge | Kg | 25 | 30 | 40 | 51 | 65 | 71 | 79 | 90 | 98 | 123 | 65×2 | 71×2 | 79×2 | 90×2 | 98×2 | 123×2 | ||
Compressor | Input power | 50HZ | KW | 42 | 55 | 72 | 83 | 100 | 126 | 141 | 165 | 187 | 980 | 200 | 525 | 282 | 330 | 374 | 412 |
60HZ | 50 | 67 | 87 | 94 | 122 | 153 | 170 | 199 | 226 | 250 | 244 | 306 | 340 | 398 | 452 | 500 | |||
Type | 5+6 Asymmetric semi-hermetic two-screw | ||||||||||||||||||
Evaporator | Model | Efficient dry shell and tube(1.65Mpa water Pressure) | |||||||||||||||||
Water Flow | 50HZ | m3/h | 28 | 37 | 49 | 55 | 69 | 93 | 103 | 125 | 140 | 159 | 138 | 186 | 206 | 250 | 280 | 318 | |
60HZ | 33 | 45 | 59 | 64 | 85 | 112 | 126 | 150 | 168 | 190 | 169 | 224 | 252 | 300 | 336 | 338 | |||
Water resistance | KPa | 48 | 48 | 49 | 50 | 53 | 55 | 60 | 60 | 63 | 66 | 68 | 65 | 65 | 68 | 68 | 68 | ||
Inlet and outlet Diameter | mm | DN80 | DN100 | DN125 | DN150 | DN200 | DN250 | ||||||||||||
Condenser | Model | Efficient shell and tube(1.65Mpa water Pressure) | |||||||||||||||||
Water Flow | 50HZ | m3/h | 35 | 47 | 62 | 69 | 87 | 117 | 129 | 158 | 175 | 199 | 173 | 234 | 258 | 316 | 350 | 398 | |
60HZ | 42 | 56 | 74 | 80 | 106 | 140 | 158 | 188 | 210 | 238 | 212 | 280 | 280 | 376 | 420 | 476 | |||
Water resistance | KPa | 42 | 42 | 46 | 46 | 48 | 52 | 54 | 56 | 58 | 67 | 67 | 42 | 42 | 46 | 46 | 48 | ||
Inlet and outlet Diameter | mm | DN80 | DN100 | DN125 | DN150 | DN125×2 | DN150×2 | ||||||||||||
Dimension | Length | mm | 2200 | 2400 | 2800 | 2900 | 3200 | 3500 | 3500 | 4000 | 4200 | 4550 | 3300 | 3500 | 3600 | 4000 | 4300 | 4600 | |
Width | 1100 | 1100 | 1250 | 1250 | 1400 | 1400 | 1400 | 1600 | 1600 | 1800 | 1800 | 1800 | 1800 | 1800 | 1900 | 1900 | |||
Height | 1500 | 1500 | 1600 | 1600 | 1600 | 1800 | 1800 | 1800 | 2000 | 2000 | 2100 | 2100 | 2200 | 2200 | 2300 | 2300 | |||
Unit Weight | Kg | 1050 | 1200 | 1250 | 1480 | 1990 | 2000 | 2100 | 2900 | 3450 | 3650 | 3800 | 4050 | 4400 | 4950 | 5480 | 5990 | ||
Operation Weight | Kg | 1170 | 1350 | 1400 | 1750 | 2200 | 2250 | 2390 | 3200 | 3770 | 3970 | 4150 | 4200 | 4650 | 5200 | 5650 | 6100 | ||
Note: 1.Cooling capacity nominal conditions:.Chilled water inlet temperature:12℃,Chilled water outlet temperature: 7℃,.Cooling water inlet temperature:32℃, outlet temperature: 37℃;Fouling factor:0.086m2℃/KW. 2.Allowable voltage fluctuation:±10%,Allow phase voltage difference:±2%. |
Application:
It is widely used in all kinds of passenger ships, cargo ships, warships and offshore oil platfroms
It is widely used in all kinds of passenger ships, cargo ships, warships and offshore oil platfroms